{"id":2555,"date":"2020-06-25T11:32:28","date_gmt":"2020-06-25T09:32:28","guid":{"rendered":"https:\/\/www.ergovisual.com\/?p=2555"},"modified":"2021-03-04T10:21:03","modified_gmt":"2021-03-04T09:21:03","slug":"hydrologic-panel-refrigeracion-datacenter-piso-falso","status":"publish","type":"post","link":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/","title":{"rendered":"HydroLogic Panel: Refrigeraci\u00f3n Datacenter por el piso falso"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">El fabricante alem\u00e1n <a href=\"https:\/\/www.weiss-dbs.es\/\"><strong>Weiss Doppelbodensysteme GmbH<\/strong><\/a> cuenta con larga experiencia en la industria IT. Nuestro partner es especialista para la refrigeraci\u00f3n de instalaciones Datacenter. Lo ha desarrollado mediante el HydroLogic Panel, sistema pionero e innovador realizando la refrigeraci\u00f3n Datacenter por el piso falso.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Las losetas activas, o bien llamadas Active Panels, se ubican en el completo del espacio inferior al suelo t\u00e9cnico. Dicha soluci\u00f3n puede sobreponerse a las dificultades m\u00e1s comunes entre los sistemas convencionales de refrigeraci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se trata del <a href=\"https:\/\/www.weiss-dbs.es\/productos\/placas-activas\/hydrologic-panel\/\"><strong>HydroLogic Panel<\/strong><\/a>, loseta de dimensiones 600mm x 600mm ubicada bajo el suelo t\u00e9cnico. La soluci\u00f3n est\u00e1 a cargo de la refrigeraci\u00f3n del Datacenter junto con una gran optimizaci\u00f3n del espacio de la sala.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/HYDROLOGIC-PANEL-3-1024x683.png\" alt=\"\" class=\"wp-image-2437\" srcset=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/HYDROLOGIC-PANEL-3-1024x683.png 1024w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/HYDROLOGIC-PANEL-3-300x200.png 300w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/HYDROLOGIC-PANEL-3-768x512.png 768w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/HYDROLOGIC-PANEL-3.png 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>Render 3D HydroLogic Panel<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Funcionamiento<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cada loseta cuenta con un intercambiador de calor en su espacio interior, junto con una potente turbina EC a cargo de la ventilaci\u00f3n y direcci\u00f3n del aire. Adem\u00e1s, de una secci\u00f3n transversal libre del 39% para el exterior de la placa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Los paneles permanecen conectados a un circuito de agua helada, la cual act\u00faa como refrigerante. En efecto, la temperatura del agua de entrada realiza la disipaci\u00f3n de calor del aire en origen al pasillo caliente. Seguidamente, la potente turbina se encarga de direccionar la ventilaci\u00f3n del aire refrigerado hacia el pasillo fr\u00edo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La modularidad del <a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\"><strong>HydroLogic Panel<\/strong><\/a> permite la instalaci\u00f3n de dos circuitos diferenciados A\/B, consiguiendo una destacable redundancia local. Asimismo, la soluci\u00f3n ofrece una capacidad de escalabilidad en caso de futuras renovaciones en la instalaci\u00f3n. Cabe apreciar, adem\u00e1s, el hecho que cada loseta act\u00faa en local. Es decir, act\u00faa en una zona determinada dedicada en exclusiva a una l\u00ednea de armarios rack.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><a href=\"https:\/\/www.weiss-dbs.es\/\"><img decoding=\"async\" src=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Cableado.png\" alt=\"\" class=\"wp-image-2463\" width=\"385\" height=\"684\" srcset=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Cableado.png 488w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Cableado-169x300.png 169w\" sizes=\"(max-width: 385px) 100vw, 385px\" \/><\/a><figcaption>Ejemplo de instalaci\u00f3n con redundancia local mediante dos circuitos A\/B diferenciados<\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">El volumen de aire necesario se ajustar\u00e1 de acuerdo con los par\u00e1metros de control que hayamos escogidos. \u00c9stos, podr\u00e1n ser seg\u00fan valores de temperatura o bien por diferencia en la presi\u00f3n del aire. Dicho factor debe configurarse previamente al pedido.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Propiedades del HydroLogic Panel<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Su formato 600mm x 600mm y una capacidad de carga de hasta 10kN por loseta le permiten trabajar con temperatura en agua de entrada 12\u00baC. En caso de disponer de placas delante y detr\u00e1s del rack, los valores de carga puede alcanzar los 20kW.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Del mismo modo, la ventaja m\u00e1s destacable de dicho innovador sistema reside en la optimizaci\u00f3n del espacio: Situando los paneles bajo el suelo t\u00e9cnico, la huella del <a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\"><strong>Datacenter <\/strong><\/a>se dedicar\u00e1 en su pr\u00e1ctica totalidad a la instalaci\u00f3n de racks 19\u00bb para el alojamiento de servidores.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La modularidad que ofrece la soluci\u00f3n resulta ideal para su adaptaci\u00f3n a futuros cambios en la instalaci\u00f3n. En todo caso, deber\u00e1 tenerse en cuenta el requerimiento de un espacio m\u00ednimo de 500mm en altura del suelo t\u00e9cnico.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La instalaci\u00f3n de Active Panels minimiza el consumo energ\u00e9tico de forma dr\u00e1stica. Detalladamente, el consumo energ\u00e9tico ser\u00e1 de 140W, y para la versi\u00f3n XL podr\u00e1 alcanzar los 400W.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Adicionalmente, seg\u00fan las condiciones clim\u00e1ticas de la instalaci\u00f3n puede darse la posibilidad de trabajar en sistema Total Free Cooling durante gran parte del a\u00f1o. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Efectivamente, el modelo <a href=\"https:\/\/www.weiss-dbs.es\/productos\/placas-activas\/hydrologic-panel\/\"><strong>HydroLogic Panel<\/strong><\/a> cuenta con dos versiones. Su versi\u00f3n est\u00e1ndar, la cual coincide con su descripci\u00f3n hasta el momento, dem\u00e1s de la versi\u00f3n XL. Dicho panel es de un mayor tama\u00f1o, requiriendo una altura m\u00ednima de 600mm en la instalaci\u00f3n del piso falso. Asimismo, sus valores de carga son mayores, alcanzando los XX kW. Su consumo energ\u00e9tico ser\u00e1 tambi\u00e9n mayor, alcanzando los 400W.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Configuraci\u00f3n personalizada para el control del flujo de aire. El <a href=\"https:\/\/www.weiss-dbs.es\/productos\/placas-activas\/hydrologic-panel\/\"><strong>HydroLogic Panel<\/strong><\/a> puede regular su intensidad por valores de temperatura o bien por presi\u00f3n del aire. Su ajuste debe definirse previa instalaci\u00f3n. Dicha capacidad confiere un excelente control del caudal del aire necesario en el pasillo. La demanda de aire seg\u00fan las necesidades de cada \u00e1rea podr\u00e1n regularse seg\u00fan requerimiento. Asimismo, para efectos externos como cambios de temperatura podr\u00e1n ver reducidos sus efectos en la operabilidad del <a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\"><strong>Datacenter<\/strong><\/a>.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\"><img decoding=\"async\" src=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Rechenzentrum-hp-1-1024x683.png\" alt=\"\" class=\"wp-image-2558\" width=\"745\" height=\"496\" srcset=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Rechenzentrum-hp-1-1024x683.png 1024w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Rechenzentrum-hp-1-300x200.png 300w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Rechenzentrum-hp-1-768x512.png 768w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Rechenzentrum-hp-1.png 1200w\" sizes=\"(max-width: 745px) 100vw, 745px\" \/><\/a><figcaption>Ejemplo Render de instalaci\u00f3n con HydroLogic Panel<\/figcaption><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Valores Destacables<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Loseta:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Dimensiones: 600mm x 600mm<\/li><li>Grosor de la Placa: 350mm, sin revestimiento<\/li><li>Materiales: PVC, HPL, caucho<\/li><li>Peso: 36kg<\/li><li>Material del Panel: Acero con recubrimiento de polvo<\/li><li>Secci\u00f3n transversal libre: 39%<\/li><li>Resistencia a Tierra: &lt; 10\u2078 Ohm (en funci\u00f3n del revestimiento)<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Valores de Carga:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Carga Puntual: 3kN<\/li><li>Carga de Rotura: &gt;6kN<\/li><li>Altura m\u00ednima de la Instalaci\u00f3n: 500mm &#8211; 2000mm<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Potencia:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Tensi\u00f3n: 230V<\/li><li>Consumo m\u00e1ximo de corriente: 140 W Versi\u00f3n est\u00e1ndar \/ 400 W Versi\u00f3n XL<\/li><li>Temperatura para agua de entrada: 12\u00baC \/ 18\u00baC<\/li><li>Caudal de agua: 1,43 m\u00b3\/h<\/li><li>Temperatura del aire de entrada al servidor: 21\u00b0 \u2013 30\u00b0C<\/li><li>Connexi\u00f3n de agua: 3 \/ 4\u2018\u2018<\/li><li>Presi\u00f3n de servicio m\u00e1ximo del intercambiador de calor: 10 bar<\/li><li>P\u00e9rdida de presi\u00f3n intercambiador de calor: 1 bar max<\/li><li>Medio refrigerante: Mezcla de agua o glicol<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Rechenzentrum-HPV-1-1024x683.jpg\" alt=\"\" class=\"wp-image-2562\" srcset=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Rechenzentrum-HPV-1-1024x683.jpg 1024w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Rechenzentrum-HPV-1-300x200.jpg 300w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Rechenzentrum-HPV-1-768x512.jpg 768w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/Rechenzentrum-HPV-1.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>Dise\u00f1o integral Datacenter con instalaci\u00f3n HydroLogic Panel<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Weiss Doppelbodensysteme ha desarrollado un innovador sistema de refrigeraci\u00f3n del Datacenter.<br \/>\nLa instalaci\u00f3n del HydroLogic Panel bajo el piso falso permite optimizar al m\u00e1ximo la huella del Datacenter.<br \/>\nGarantiza la refrigeraci\u00f3n de tu instalaci\u00f3n adem\u00e1s de contar con una destacable modularidad para futuras renovaciones en el CPD.<\/p>\n","protected":false},"author":7,"featured_media":2575,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[46],"tags":[44],"class_list":["post-2555","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-datacenter-es","tag-datacenter-2"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>HydroLogic Panel: Refrigeraci\u00f3n Datacenter por el piso falso - ErgoVisual<\/title>\n<meta name=\"description\" content=\"Refrigeraci\u00f3n Datacenter por el piso falso. HydroLogic Panel para la climatizaci\u00f3n del CPD. Optimiza la huella del Datacenter.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HydroLogic Panel: Refrigeraci\u00f3n Datacenter por el piso falso - ErgoVisual\" \/>\n<meta property=\"og:description\" content=\"Refrigeraci\u00f3n Datacenter por el piso falso. HydroLogic Panel para la climatizaci\u00f3n del CPD. Optimiza la huella del Datacenter.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/\" \/>\n<meta property=\"og:site_name\" content=\"ErgoVisual\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-25T09:32:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-03-04T09:21:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/high_v5.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1948\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Albert San Jos\u00e9\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Albert San Jos\u00e9\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/\"},\"author\":{\"name\":\"Albert San Jos\u00e9\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/#\/schema\/person\/8671ae1b31596122e80c5645c58ce8e9\"},\"headline\":\"HydroLogic Panel: Refrigeraci\u00f3n Datacenter por el piso falso\",\"datePublished\":\"2020-06-25T09:32:28+00:00\",\"dateModified\":\"2021-03-04T09:21:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/\"},\"wordCount\":875,\"publisher\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/high_v5.jpg\",\"keywords\":[\"datacenter\"],\"articleSection\":[\"Datacenter\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/\",\"url\":\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/\",\"name\":\"HydroLogic Panel: Refrigeraci\u00f3n Datacenter por el piso falso - ErgoVisual\",\"isPartOf\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/high_v5.jpg\",\"datePublished\":\"2020-06-25T09:32:28+00:00\",\"dateModified\":\"2021-03-04T09:21:03+00:00\",\"description\":\"Refrigeraci\u00f3n Datacenter por el piso falso. HydroLogic Panel para la climatizaci\u00f3n del CPD. Optimiza la huella del Datacenter.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#primaryimage\",\"url\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/high_v5.jpg\",\"contentUrl\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/high_v5.jpg\",\"width\":2560,\"height\":1948},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/www.ergovisual.com\/es\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HydroLogic Panel: Refrigeraci\u00f3n Datacenter por el piso falso\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/#website\",\"url\":\"https:\/\/www.ergovisual.com\/es\/\",\"name\":\"ErgoVisual\",\"description\":\"Control Room Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ergovisual.com\/es\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/#organization\",\"name\":\"INTAM ERGOVISUAL SLU\",\"url\":\"https:\/\/www.ergovisual.com\/es\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2022\/03\/logo-ergovisual.svg\",\"contentUrl\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2022\/03\/logo-ergovisual.svg\",\"caption\":\"INTAM ERGOVISUAL SLU\"},\"image\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/ergovisual\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/#\/schema\/person\/8671ae1b31596122e80c5645c58ce8e9\",\"name\":\"Albert San Jos\u00e9\",\"sameAs\":[\"http:\/\/www.ergovisual.com\"],\"url\":\"https:\/\/www.ergovisual.com\/es\/author\/albert_ergovis\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HydroLogic Panel: Refrigeraci\u00f3n Datacenter por el piso falso - ErgoVisual","description":"Refrigeraci\u00f3n Datacenter por el piso falso. HydroLogic Panel para la climatizaci\u00f3n del CPD. Optimiza la huella del Datacenter.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/","og_locale":"es_ES","og_type":"article","og_title":"HydroLogic Panel: Refrigeraci\u00f3n Datacenter por el piso falso - ErgoVisual","og_description":"Refrigeraci\u00f3n Datacenter por el piso falso. HydroLogic Panel para la climatizaci\u00f3n del CPD. Optimiza la huella del Datacenter.","og_url":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/","og_site_name":"ErgoVisual","article_published_time":"2020-06-25T09:32:28+00:00","article_modified_time":"2021-03-04T09:21:03+00:00","og_image":[{"width":2560,"height":1948,"url":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/high_v5.jpg","type":"image\/jpeg"}],"author":"Albert San Jos\u00e9","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Albert San Jos\u00e9","Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#article","isPartOf":{"@id":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/"},"author":{"name":"Albert San Jos\u00e9","@id":"https:\/\/www.ergovisual.com\/es\/#\/schema\/person\/8671ae1b31596122e80c5645c58ce8e9"},"headline":"HydroLogic Panel: Refrigeraci\u00f3n Datacenter por el piso falso","datePublished":"2020-06-25T09:32:28+00:00","dateModified":"2021-03-04T09:21:03+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/"},"wordCount":875,"publisher":{"@id":"https:\/\/www.ergovisual.com\/es\/#organization"},"image":{"@id":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/high_v5.jpg","keywords":["datacenter"],"articleSection":["Datacenter"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/","url":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/","name":"HydroLogic Panel: Refrigeraci\u00f3n Datacenter por el piso falso - ErgoVisual","isPartOf":{"@id":"https:\/\/www.ergovisual.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#primaryimage"},"image":{"@id":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/high_v5.jpg","datePublished":"2020-06-25T09:32:28+00:00","dateModified":"2021-03-04T09:21:03+00:00","description":"Refrigeraci\u00f3n Datacenter por el piso falso. HydroLogic Panel para la climatizaci\u00f3n del CPD. Optimiza la huella del Datacenter.","breadcrumb":{"@id":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#primaryimage","url":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/high_v5.jpg","contentUrl":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/high_v5.jpg","width":2560,"height":1948},{"@type":"BreadcrumbList","@id":"https:\/\/www.ergovisual.com\/es\/hydrologic-panel-refrigeracion-datacenter-piso-falso\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.ergovisual.com\/es\/"},{"@type":"ListItem","position":2,"name":"HydroLogic Panel: Refrigeraci\u00f3n Datacenter por el piso falso"}]},{"@type":"WebSite","@id":"https:\/\/www.ergovisual.com\/es\/#website","url":"https:\/\/www.ergovisual.com\/es\/","name":"ErgoVisual","description":"Control Room Solutions","publisher":{"@id":"https:\/\/www.ergovisual.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ergovisual.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.ergovisual.com\/es\/#organization","name":"INTAM ERGOVISUAL SLU","url":"https:\/\/www.ergovisual.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.ergovisual.com\/es\/#\/schema\/logo\/image\/","url":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2022\/03\/logo-ergovisual.svg","contentUrl":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2022\/03\/logo-ergovisual.svg","caption":"INTAM ERGOVISUAL SLU"},"image":{"@id":"https:\/\/www.ergovisual.com\/es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/ergovisual"]},{"@type":"Person","@id":"https:\/\/www.ergovisual.com\/es\/#\/schema\/person\/8671ae1b31596122e80c5645c58ce8e9","name":"Albert San Jos\u00e9","sameAs":["http:\/\/www.ergovisual.com"],"url":"https:\/\/www.ergovisual.com\/es\/author\/albert_ergovis\/"}]}},"_links":{"self":[{"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/posts\/2555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/comments?post=2555"}],"version-history":[{"count":0,"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/posts\/2555\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/media\/2575"}],"wp:attachment":[{"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/media?parent=2555"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/categories?post=2555"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/tags?post=2555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}