{"id":2755,"date":"2020-07-15T16:46:02","date_gmt":"2020-07-15T14:46:02","guid":{"rendered":"https:\/\/www.ergovisual.com\/?p=2755"},"modified":"2021-03-04T10:19:55","modified_gmt":"2021-03-04T09:19:55","slug":"panel-expansion-directa","status":"publish","type":"post","link":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/","title":{"rendered":"Panel Expansi\u00f3n Directa: Refrigeraci\u00f3n Datacenter"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">La trayectoria de nuestro partner Weiss Doppelbodensysteme en los mercados IT y Datacenter, ha permitido el desarrollo del <strong><a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\">Panel por Expansi\u00f3n Directa<\/a><\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">De acuerdo con el Cat\u00e1logo de Producto Weiss, nuestro m\u00e1s reciente lanzamiento es fiel al innovador sistema de refrigeraci\u00f3n In-Floor para Datacenters. En efecto, la versi\u00f3n en Expansi\u00f3n Directa ubica el panel bajo el suelo t\u00e9cnico. As\u00ed optimizando la huella del <strong><a href=\"https:\/\/www.weiss-dbs.es\/\">Datacenter<\/a><\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En esta ocasi\u00f3n, el nuevo Panel DX trabaja con circuito de gas, en alternativa a los previos circuitos de agua helada.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.14-1024x576.png\" alt=\"\" class=\"wp-image-2588\" srcset=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.14-1024x576.png 1024w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.14-300x169.png 300w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.14-768x432.png 768w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.14-1536x864.png 1536w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.14.png 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Funciones<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Las dimensiones de la versi\u00f3n DX son de 1200mm x 600mm x 550mm. Equipado con 4 turbinas EC e intercambiadores de calor DX con una superficie libre del 44%.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Los Paneles por <strong><a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\">Expansi\u00f3n Directa<\/a><\/strong> se ubicar\u00e1n bajo el suelo t\u00e9cnico situados frente cada l\u00ednea de racks. La loseta se podr\u00e1 configurar para diversas funciones. En modo aspiraci\u00f3n en el pasillo caliente y\/o en modo ventilaci\u00f3n en el pasillo fr\u00edo. De este modo, facilitando la direcci\u00f3n del aire seg\u00fan las necesidades en la instalaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El Panel est\u00e1 a cargo de la climatizaci\u00f3n de la sala, actuando el gas como agente refrigerante. Por ello, el <strong><a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\">Datacenter <\/a><\/strong>podr\u00e1 trabajar con bajas temperaturas. La presencia de humidificadores y condensadores son claves para una ventilaci\u00f3n de precisi\u00f3n en el CPD.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Adicionalmente, las ventiladores EC se encargan de la circulaci\u00f3n del aire. Dirigiendo el aire refrigerado a los racks en pasillo fr\u00edo. Cada panel alcanzar\u00e1 un flujo de aire de hasta 6.000m3\/h.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En relaci\u00f3n a los sistemas de control. Los ventiladores reaccionan a los cambios de temperatura en la sala. Efectivamente, la reducci\u00f3n o el aumento del flujo de aire deseado se configurar\u00e1 en base dos valores. Bien por diferencia de temperatura, o bien por presi\u00f3n del aire de la sala. No obstante, su configuraci\u00f3n deber\u00e1 hacerse previamente.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\"><img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.16-1024x576.png\" alt=\"\" class=\"wp-image-2591\" srcset=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.16-1024x576.png 1024w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.16-300x169.png 300w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.16-768x432.png 768w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.16-1536x864.png 1536w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.16.png 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Propiedades del Panel en Expansi\u00f3n Directa (DX)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El <strong><a href=\"https:\/\/www.weiss-dbs.es\/\">Panel por Expansi\u00f3n Directa<\/a><\/strong> puede alcanzar cargas \u00fatiles de hasta 30Kw por unidad. Su funcionamiento ser\u00e1 en base gas como agente refrigerador, as\u00ed trabajando con temperaturas de 5\u00baC de evaporaci\u00f3n. Por eso, el Panel est\u00e1 equipado con humidificadores, as\u00ed como control de condensados.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El Panel requiere de una altura m\u00ednima de instalaci\u00f3n de 550mm. No obstante, su ubicaci\u00f3n bajo el piso falso confiere una gran optimizaci\u00f3n de huella disponible en el <strong><a href=\"https:\/\/www.weiss-dbs.es\/\">Datacenter<\/a><\/strong>, alojando servidores en los racks 19\u00bb. Adicionalmente, ofrece una notable modularidad para futuras renovaciones. Adem\u00e1s, en caso de reparaci\u00f3n, el Panel DX<a href=\"https:\/\/www.weiss-dbs.es\/\"> <\/a>contin\u00faa trabajando sin mayores afectaciones.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Respecto los sistemas de control del aire. Seg\u00fan especificado, el flujo de aire se regula en base 2 valores: bien por temperatura del aire, o bien por presi\u00f3n del aire. Su ajuste debe definirse previamente. Efectivamente, todos los sistemas garantizan un control absoluto del flujo de aire deseado en cada \u00e1rea.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">De forma m\u00e1s concreta, la soluci\u00f3n ofrece diversos sistemas de control. V\u00eda control remoto, integraci\u00f3n snmp, Bacnet, entre otras opciones.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\"><img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.18-1024x576.png\" alt=\"\" class=\"wp-image-2595\" srcset=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.18-1024x576.png 1024w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.18-300x169.png 300w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.18-768x432.png 768w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.18-1536x864.png 1536w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.18.png 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Valores Destacables<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Loseta:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Dimensiones: 1200mm x 600mm x 550mm<\/li><li>Altura: 535mm<\/li><li>Material: PVC, HPL, goma<\/li><li>Peso: 80kg \/ unidad<\/li><li>Acabado: Acero con recubrimiento en polvo<\/li><li>Superficie transversal libre: 44%<\/li><li>Resistencia al suelo: &lt; 10\u2078 Ohm (seg\u00fan cubrimiento)<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Cargas \u00datiles:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Carga puntual: 5kN<\/li><li>Carga m\u00e1xima: &gt;6kN<\/li><li>Altura: 600mm &#8211; 2000mm<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Energ\u00eda:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Refrigeraci\u00f3n: Hasta 30Kw \/ unidad<\/li><li>Consumo Energ\u00e9tico: 720 W<\/li><li>Voltaje: 230 V<\/li><li>Flujo de Aire: 6.000m3 \/ h<\/li><li>Humidificador: Integrado<\/li><li>Gesti\u00f3n de condensados: Integrado<\/li><li>Temperatura de Evaporaci\u00f3n: 5\u00baC<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/www.ergovisual.com\/es\/datacenters\/\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.17-1024x576.png\" alt=\"\" class=\"wp-image-2599\" srcset=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.17-1024x576.png 1024w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.17-300x169.png 300w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.17-768x432.png 768w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.17-1536x864.png 1536w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/untitled.17.png 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n","protected":false},"excerpt":{"rendered":"<p>La trayectoria de nuestro partner Weiss Doppelbodensysteme en los mercados IT y Datacenter, ha permitido el desarrollo del Panel por Expansi\u00f3n Directa.<br \/>\nEn esta ocasi\u00f3n, el nuevo Panel DX trabaja con circuito de gas, en alternativa a los previos circuitos de agua helada.<br \/>\nConsigue una importante optimizaci\u00f3n de la huella del Datacenter, garantizando la refrigeraci\u00f3n del CPD.<\/p>\n","protected":false},"author":7,"featured_media":2814,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[46],"tags":[44],"class_list":["post-2755","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-datacenter-es","tag-datacenter-2"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Panel Expansi\u00f3n Directa: Refrigeraci\u00f3n Datacenter - ErgoVisual<\/title>\n<meta name=\"description\" content=\"Panel Expansi\u00f3n Directa en Datacenter. Nueva versi\u00f3n Box Panel en Expansi\u00f3n Directa. Refrigeraci\u00f3n Datacenter por el piso falso. Climatizaci\u00f3n In-Floor.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Panel Expansi\u00f3n Directa: Refrigeraci\u00f3n Datacenter - ErgoVisual\" \/>\n<meta property=\"og:description\" content=\"Panel Expansi\u00f3n Directa en Datacenter. Nueva versi\u00f3n Box Panel en Expansi\u00f3n Directa. Refrigeraci\u00f3n Datacenter por el piso falso. Climatizaci\u00f3n In-Floor.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/\" \/>\n<meta property=\"og:site_name\" content=\"ErgoVisual\" \/>\n<meta property=\"article:published_time\" content=\"2020-07-15T14:46:02+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-03-04T09:19:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/07\/Render-DX-Box-Panel-Components-Detail-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1393\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Albert San Jos\u00e9\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Albert San Jos\u00e9\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/\"},\"author\":{\"name\":\"Albert San Jos\u00e9\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/#\/schema\/person\/8671ae1b31596122e80c5645c58ce8e9\"},\"headline\":\"Panel Expansi\u00f3n Directa: Refrigeraci\u00f3n Datacenter\",\"datePublished\":\"2020-07-15T14:46:02+00:00\",\"dateModified\":\"2021-03-04T09:19:55+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/\"},\"wordCount\":604,\"publisher\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/07\/Render-DX-Box-Panel-Components-Detail-scaled.jpg\",\"keywords\":[\"datacenter\"],\"articleSection\":[\"Datacenter\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/\",\"url\":\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/\",\"name\":\"Panel Expansi\u00f3n Directa: Refrigeraci\u00f3n Datacenter - ErgoVisual\",\"isPartOf\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/07\/Render-DX-Box-Panel-Components-Detail-scaled.jpg\",\"datePublished\":\"2020-07-15T14:46:02+00:00\",\"dateModified\":\"2021-03-04T09:19:55+00:00\",\"description\":\"Panel Expansi\u00f3n Directa en Datacenter. Nueva versi\u00f3n Box Panel en Expansi\u00f3n Directa. Refrigeraci\u00f3n Datacenter por el piso falso. Climatizaci\u00f3n In-Floor.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#primaryimage\",\"url\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/07\/Render-DX-Box-Panel-Components-Detail-scaled.jpg\",\"contentUrl\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/07\/Render-DX-Box-Panel-Components-Detail-scaled.jpg\",\"width\":2560,\"height\":1393},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/www.ergovisual.com\/es\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Panel Expansi\u00f3n Directa: Refrigeraci\u00f3n Datacenter\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/#website\",\"url\":\"https:\/\/www.ergovisual.com\/es\/\",\"name\":\"ErgoVisual\",\"description\":\"Control Room Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ergovisual.com\/es\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/#organization\",\"name\":\"INTAM ERGOVISUAL SLU\",\"url\":\"https:\/\/www.ergovisual.com\/es\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2022\/03\/logo-ergovisual.svg\",\"contentUrl\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2022\/03\/logo-ergovisual.svg\",\"caption\":\"INTAM ERGOVISUAL SLU\"},\"image\":{\"@id\":\"https:\/\/www.ergovisual.com\/es\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/ergovisual\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.ergovisual.com\/es\/#\/schema\/person\/8671ae1b31596122e80c5645c58ce8e9\",\"name\":\"Albert San Jos\u00e9\",\"sameAs\":[\"http:\/\/www.ergovisual.com\"],\"url\":\"https:\/\/www.ergovisual.com\/es\/author\/albert_ergovis\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Panel Expansi\u00f3n Directa: Refrigeraci\u00f3n Datacenter - ErgoVisual","description":"Panel Expansi\u00f3n Directa en Datacenter. Nueva versi\u00f3n Box Panel en Expansi\u00f3n Directa. Refrigeraci\u00f3n Datacenter por el piso falso. Climatizaci\u00f3n In-Floor.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/","og_locale":"es_ES","og_type":"article","og_title":"Panel Expansi\u00f3n Directa: Refrigeraci\u00f3n Datacenter - ErgoVisual","og_description":"Panel Expansi\u00f3n Directa en Datacenter. Nueva versi\u00f3n Box Panel en Expansi\u00f3n Directa. Refrigeraci\u00f3n Datacenter por el piso falso. Climatizaci\u00f3n In-Floor.","og_url":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/","og_site_name":"ErgoVisual","article_published_time":"2020-07-15T14:46:02+00:00","article_modified_time":"2021-03-04T09:19:55+00:00","og_image":[{"width":2560,"height":1393,"url":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/07\/Render-DX-Box-Panel-Components-Detail-scaled.jpg","type":"image\/jpeg"}],"author":"Albert San Jos\u00e9","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Albert San Jos\u00e9","Tiempo de lectura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#article","isPartOf":{"@id":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/"},"author":{"name":"Albert San Jos\u00e9","@id":"https:\/\/www.ergovisual.com\/es\/#\/schema\/person\/8671ae1b31596122e80c5645c58ce8e9"},"headline":"Panel Expansi\u00f3n Directa: Refrigeraci\u00f3n Datacenter","datePublished":"2020-07-15T14:46:02+00:00","dateModified":"2021-03-04T09:19:55+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/"},"wordCount":604,"publisher":{"@id":"https:\/\/www.ergovisual.com\/es\/#organization"},"image":{"@id":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/07\/Render-DX-Box-Panel-Components-Detail-scaled.jpg","keywords":["datacenter"],"articleSection":["Datacenter"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/","url":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/","name":"Panel Expansi\u00f3n Directa: Refrigeraci\u00f3n Datacenter - ErgoVisual","isPartOf":{"@id":"https:\/\/www.ergovisual.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#primaryimage"},"image":{"@id":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/07\/Render-DX-Box-Panel-Components-Detail-scaled.jpg","datePublished":"2020-07-15T14:46:02+00:00","dateModified":"2021-03-04T09:19:55+00:00","description":"Panel Expansi\u00f3n Directa en Datacenter. Nueva versi\u00f3n Box Panel en Expansi\u00f3n Directa. Refrigeraci\u00f3n Datacenter por el piso falso. Climatizaci\u00f3n In-Floor.","breadcrumb":{"@id":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#primaryimage","url":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/07\/Render-DX-Box-Panel-Components-Detail-scaled.jpg","contentUrl":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/07\/Render-DX-Box-Panel-Components-Detail-scaled.jpg","width":2560,"height":1393},{"@type":"BreadcrumbList","@id":"https:\/\/www.ergovisual.com\/es\/panel-expansion-directa\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.ergovisual.com\/es\/"},{"@type":"ListItem","position":2,"name":"Panel Expansi\u00f3n Directa: Refrigeraci\u00f3n Datacenter"}]},{"@type":"WebSite","@id":"https:\/\/www.ergovisual.com\/es\/#website","url":"https:\/\/www.ergovisual.com\/es\/","name":"ErgoVisual","description":"Control Room Solutions","publisher":{"@id":"https:\/\/www.ergovisual.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ergovisual.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.ergovisual.com\/es\/#organization","name":"INTAM ERGOVISUAL SLU","url":"https:\/\/www.ergovisual.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.ergovisual.com\/es\/#\/schema\/logo\/image\/","url":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2022\/03\/logo-ergovisual.svg","contentUrl":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2022\/03\/logo-ergovisual.svg","caption":"INTAM ERGOVISUAL SLU"},"image":{"@id":"https:\/\/www.ergovisual.com\/es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/ergovisual"]},{"@type":"Person","@id":"https:\/\/www.ergovisual.com\/es\/#\/schema\/person\/8671ae1b31596122e80c5645c58ce8e9","name":"Albert San Jos\u00e9","sameAs":["http:\/\/www.ergovisual.com"],"url":"https:\/\/www.ergovisual.com\/es\/author\/albert_ergovis\/"}]}},"_links":{"self":[{"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/posts\/2755","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/comments?post=2755"}],"version-history":[{"count":0,"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/posts\/2755\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/media\/2814"}],"wp:attachment":[{"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/media?parent=2755"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/categories?post=2755"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ergovisual.com\/es\/wp-json\/wp\/v2\/tags?post=2755"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}