{"id":4112,"date":"2021-03-04T10:04:58","date_gmt":"2021-03-04T09:04:58","guid":{"rendered":"https:\/\/www.ergovisual.com\/?p=4112"},"modified":"2021-03-04T10:05:00","modified_gmt":"2021-03-04T09:05:00","slug":"refroidissement-datacenter","status":"publish","type":"post","link":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/","title":{"rendered":"HydroLogic Panel: Refroidissement Datacenter via le plancher sur\u00e9lev\u00e9"},"content":{"rendered":"\n<p>Le fabricant allemand <a href=\"https:\/\/www.weiss-dbs.com\/\">Weiss Doppelbodensysteme GmbH<\/a> a une longue exp\u00e9rience dans l&rsquo;industrie informatique. Notre partenaire est un sp\u00e9cialiste du refroidissement des installations de <a href=\"https:\/\/www.ergovisual.com\/fr\/datacenters\/\">centre de donn\u00e9es<\/a>. Il a \u00e9t\u00e9 d\u00e9velopp\u00e9 \u00e0 l&rsquo;aide du HydroLogic Panel, un syst\u00e8me pionnier et innovant qui effectue le refroidissement Datacenter \u00e0 travers le faux plancher.<\/p>\n\n\n\n<p>Les tuiles actives, ou appel\u00e9es panneaux actifs, sont situ\u00e9es dans tout l&rsquo;espace sous le plancher sur\u00e9lev\u00e9. Une telle solution peut surmonter les difficult\u00e9s les plus courantes parmi les syst\u00e8mes de r\u00e9frig\u00e9ration conventionnels.<\/p>\n\n\n\n<p>Il s&rsquo;agit du <a href=\"https:\/\/www.weiss-dbs.com\/products\/active-panels\/hydrologic-panel\/\">HydroLogic Panel<\/a>, une tuile de 600 mm x 600 mm situ\u00e9e sous le plancher sur\u00e9lev\u00e9. La solution est en charge du refroidissement Datacenter avec une grande optimisation de l&rsquo;espace de la pi\u00e8ce.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3-1024x683.png\" alt=\"\" class=\"wp-image-3856\" width=\"679\" height=\"452\" srcset=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3-1024x683.png 1024w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3-300x200.png 300w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3-768x512.png 768w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3.png 1200w\" sizes=\"(max-width: 679px) 100vw, 679px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Fonctionnement<\/h3>\n\n\n\n<p>Chaque tuile poss\u00e8de un \u00e9changeur de chaleur dans son espace int\u00e9rieur, ainsi qu&rsquo;une puissante turbine EC en charge de la ventilation et de la direction de l&rsquo;air. De plus, une section transversale libre de 39% pour l&rsquo;ext\u00e9rieur de la plaque.<\/p>\n\n\n\n<p>Les panneaux restent connect\u00e9s \u00e0 un circuit d&rsquo;eau glac\u00e9e, qui agit comme un r\u00e9frig\u00e9rant. En effet, la temp\u00e9rature de l&rsquo;eau en entr\u00e9e dissipe la chaleur de l&rsquo;air \u00e0 la source vers l&rsquo;all\u00e9e chaude. Ensuite, la puissante turbine est charg\u00e9e d&rsquo;orienter la ventilation de l&rsquo;air refroidi vers l&rsquo;all\u00e9e froide. La modularit\u00e9 du HydroLogic Panel permet l&rsquo;installation de deux circuits A \/ B diff\u00e9renci\u00e9s, r\u00e9alisant une redondance locale remarquable. La solution offre \u00e9galement une \u00e9volutivit\u00e9 en cas de futures r\u00e9novations d&rsquo;installations. Il faut \u00e9galement appr\u00e9cier le fait que chaque tuile agit localement. En d&rsquo;autres termes, il op\u00e8re dans une zone sp\u00e9cifique d\u00e9di\u00e9e exclusivement \u00e0 une ligne d&rsquo;armoires rack, contribuant \u00e0 am\u00e9liorer le refroidissement Datacenter.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/10\/Cableado.png\" alt=\"\" class=\"wp-image-3432\" width=\"274\" height=\"488\" srcset=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/10\/Cableado.png 488w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/10\/Cableado-169x300.png 169w\" sizes=\"(max-width: 274px) 100vw, 274px\" \/><\/figure><\/div>\n\n\n\n<p>Le volume d&rsquo;air n\u00e9cessaire sera ajust\u00e9 en fonction des param\u00e8tres de contr\u00f4le que nous avons choisis. Celles-ci peuvent \u00eatre fonction des valeurs de temp\u00e9rature ou de la diff\u00e9rence de pression d&rsquo;air. Ce facteur doit \u00eatre configur\u00e9 avant la commande.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Propri\u00e9t\u00e9s du <a href=\"https:\/\/www.weiss-dbs.com\/products\/active-panels\/hydrologic-panel\/\">HydroLogic Panel<\/a><\/h3>\n\n\n\n<p>Son format 600 mm x 600 mm et une capacit\u00e9 de charge allant jusqu&rsquo;\u00e0 10 kN par carreau lui permettent de travailler avec une temp\u00e9rature d&rsquo;eau d&rsquo;entr\u00e9e de 12 \u00b0 C. En cas de plaques \u00e0 l&rsquo;avant et \u00e0 l&rsquo;arri\u00e8re du rack, les valeurs de charge peuvent atteindre 20 kW.<\/p>\n\n\n\n<p>De la m\u00eame mani\u00e8re, l&rsquo;avantage le plus notable de ce syst\u00e8me innovant r\u00e9side dans l&rsquo;optimisation de l&rsquo;espace: en pla\u00e7ant les panneaux sous le plancher sur\u00e9lev\u00e9, l&#8217;empreinte du Datacenter sera consacr\u00e9e presque enti\u00e8rement \u00e0 l&rsquo;installation de racks 19 \u00bbpour l&rsquo;h\u00e9bergement de serveurs .<\/p>\n\n\n\n<p>La modularit\u00e9 offerte par la solution est id\u00e9ale pour son adaptation aux \u00e9volutions futures de l&rsquo;installation. Dans tous les cas, l&rsquo;exigence d&rsquo;un espace minimum de 500 mm de hauteur par rapport au plancher sur\u00e9lev\u00e9 doit \u00eatre prise en compte.<\/p>\n\n\n\n<p>L&rsquo;installation de panneaux actifs minimise consid\u00e9rablement la consommation d&rsquo;\u00e9nergie. Dans le d\u00e9tail, la consommation d&rsquo;\u00e9nergie sera de 140W, et pour la version XL, elle peut atteindre 400W.<\/p>\n\n\n\n<p>De plus, selon les conditions climatiques de l&rsquo;installation, il peut \u00eatre possible de travailler dans le syst\u00e8me Total Free Cooling pendant une grande partie de l&rsquo;ann\u00e9e.<\/p>\n\n\n\n<p>En effet, le mod\u00e8le HydroLogic Panel a deux versions. Sa version standard, qui correspond \u00e0 sa description jusqu&rsquo;\u00e0 pr\u00e9sent, autre que la version XL. Ledit panneau est de plus grande taille, n\u00e9cessitant une hauteur minimale de 600 mm lors de la pose du faux plancher. De plus, leurs valeurs de charge sont plus \u00e9lev\u00e9es, atteignant XX kW. Sa consommation d&rsquo;\u00e9nergie sera \u00e9galement plus \u00e9lev\u00e9e, atteignant 400W.<\/p>\n\n\n\n<p>Param\u00e8tres personnalis\u00e9s pour le contr\u00f4le du flux d&rsquo;air. Le HydroLogic Panel peut r\u00e9guler son intensit\u00e9 par des valeurs de temp\u00e9rature ou par pression d&rsquo;air. Son r\u00e9glage doit \u00eatre d\u00e9fini avant l&rsquo;installation. Cette capacit\u00e9 permet un excellent contr\u00f4le du d\u00e9bit d&rsquo;air requis dans le couloir. La demande d&rsquo;air en fonction des besoins de chaque zone peut \u00eatre r\u00e9gul\u00e9e au besoin. De m\u00eame, pour les effets externes tels que les changements de temp\u00e9rature, leurs effets sur l&rsquo;op\u00e9rabilit\u00e9 du <a href=\"https:\/\/www.ergovisual.com\/fr\/datacenters\/\">centre de donn\u00e9es<\/a> peuvent \u00eatre r\u00e9duits.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><a href=\"https:\/\/www.weiss-dbs.com\/products\/active-panels\/hydrologic-panel\/\"><img decoding=\"async\" src=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/11\/Rechenzentrum-hp-1024x683.png\" alt=\"\" class=\"wp-image-3551\" width=\"679\" height=\"452\" srcset=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/11\/Rechenzentrum-hp-1024x683.png 1024w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/11\/Rechenzentrum-hp-300x200.png 300w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/11\/Rechenzentrum-hp-768x512.png 768w, https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/11\/Rechenzentrum-hp.png 1200w\" sizes=\"(max-width: 679px) 100vw, 679px\" \/><\/a><\/figure><\/div>\n\n\n\n<p><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.weiss-dbs.com\/products\/active-panels\/hydrologic-panel\/\">Des valeurs exceptionnelles<\/a><\/h3>\n\n\n\n<p>Tuile:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Dimensions: 600 mm x 600 mm<\/li><li>\u00c9paisseur de la plaque: 350 mm, non rev\u00eatue<\/li><li>Mat\u00e9riaux: PVC, HPL, caoutchouc<\/li><li>Poids: 36kg<\/li><li>Mat\u00e9riau du panneau: acier enduit de poudre<\/li><li>Section transversale libre: 39%<\/li><li>R\u00e9sistance \u00e0 la terre: &lt;10\u2078 Ohm (selon le rev\u00eatement)<\/li><\/ul>\n\n\n\n<p>Valeurs de charge:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Charge ponctuelle: 3kN<\/li><li>Charge de rupture:&gt; 6kN<\/li><li>Hauteur d&rsquo;installation minimale: 500 mm &#8211; 2000 mm<\/li><\/ul>\n\n\n\n<p>Puissance:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Tension: 230V<\/li><li>Consommation de courant maximale: 140 W version standard \/ 400 W version XL<\/li><li>Temp\u00e9rature de l&rsquo;eau d&rsquo;entr\u00e9e: 12 \u00b0 C \/ 18 \u00b0 C<\/li><li>D\u00e9bit d&rsquo;eau: 1,43 m\u00b3 \/ h<\/li><li>Temp\u00e9rature de l&rsquo;air d&rsquo;entr\u00e9e du serveur: 21 \u00b0 &#8211; 30 \u00b0 C<\/li><li>Raccordement \u00e0 l&rsquo;eau: 3\/4 \u00ab\u00a0\u00a0\u00bb<\/li><li>Pression de service maximale de l&rsquo;\u00e9changeur de chaleur: 10 bar<\/li><li>Perte de charge de l&rsquo;\u00e9changeur de chaleur: 1 bar max<\/li><li>Milieu de refroidissement: m\u00e9lange d&rsquo;eau ou de glycol<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><a href=\"https:\/\/www.ergovisual.com\/fr\/\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/11\/Rechenzentrum-HPV-2-1024x683.jpg\" alt=\"\" class=\"wp-image-3567\" width=\"600\" height=\"399\" \/><\/a><\/figure><\/div>\n","protected":false},"excerpt":{"rendered":"<p>HydroLogic Panel, est une tuile situ\u00e9e sous le plancher sur\u00e9lev\u00e9 qui est en charge du refroidissement Datacenter avec une grande optimisation d&rsquo;espace.<\/p>\n<p>Chaque tuile poss\u00e8de un \u00e9changeur de chaleur dans son espace int\u00e9rieur, ainsi qu&rsquo;une puissante turbine EC en charge de la ventilation et de la direction de l&rsquo;air. De plus, une section transversale libre de 39% pour l&rsquo;ext\u00e9rieur de la plaque.<\/p>\n<p>Le volume d&rsquo;air n\u00e9cessaire sera ajust\u00e9 en fonction des param\u00e8tres de contr\u00f4le que nous avons choisis. Celles-ci peuvent \u00eatre fonction des valeurs de temp\u00e9rature ou de la diff\u00e9rence de pression d&rsquo;air. Ce facteur doit \u00eatre configur\u00e9 avant la commande.<\/p>\n","protected":false},"author":7,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[50],"class_list":["post-4112","post","type-post","status-publish","format-standard","hentry","category-datacenter-fr","tag-datacenter-3"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>HydroLogic Panel: Refroidissement Datacenter via le plancher sur\u00e9lev\u00e9 - ErgoVisual<\/title>\n<meta name=\"description\" content=\"HydroLogic Panel, est une tuile situ\u00e9e sous le plancher sur\u00e9lev\u00e9 qui est en charge du refroidissement Datacenter avec une grande optimisation d&#039;espace.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HydroLogic Panel: Refroidissement Datacenter via le plancher sur\u00e9lev\u00e9 - ErgoVisual\" \/>\n<meta property=\"og:description\" content=\"HydroLogic Panel, est une tuile situ\u00e9e sous le plancher sur\u00e9lev\u00e9 qui est en charge du refroidissement Datacenter avec une grande optimisation d&#039;espace.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/\" \/>\n<meta property=\"og:site_name\" content=\"ErgoVisual\" \/>\n<meta property=\"article:published_time\" content=\"2021-03-04T09:04:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-03-04T09:05:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/high_v5.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1948\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Albert San Jos\u00e9\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Albert San Jos\u00e9\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/\"},\"author\":{\"name\":\"Albert San Jos\u00e9\",\"@id\":\"https:\/\/www.ergovisual.com\/fr\/#\/schema\/person\/8671ae1b31596122e80c5645c58ce8e9\"},\"headline\":\"HydroLogic Panel: Refroidissement Datacenter via le plancher sur\u00e9lev\u00e9\",\"datePublished\":\"2021-03-04T09:04:58+00:00\",\"dateModified\":\"2021-03-04T09:05:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/\"},\"wordCount\":844,\"publisher\":{\"@id\":\"https:\/\/www.ergovisual.com\/fr\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3-1024x683.png\",\"keywords\":[\"datacenter\"],\"articleSection\":[\"Datacenter\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/\",\"url\":\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/\",\"name\":\"HydroLogic Panel: Refroidissement Datacenter via le plancher sur\u00e9lev\u00e9 - ErgoVisual\",\"isPartOf\":{\"@id\":\"https:\/\/www.ergovisual.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3-1024x683.png\",\"datePublished\":\"2021-03-04T09:04:58+00:00\",\"dateModified\":\"2021-03-04T09:05:00+00:00\",\"description\":\"HydroLogic Panel, est une tuile situ\u00e9e sous le plancher sur\u00e9lev\u00e9 qui est en charge du refroidissement Datacenter avec une grande optimisation d'espace.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#primaryimage\",\"url\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3-1024x683.png\",\"contentUrl\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3-1024x683.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/www.ergovisual.com\/fr\/service-de-salle-de-controle-360o\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HydroLogic Panel: Refroidissement Datacenter via le plancher sur\u00e9lev\u00e9\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ergovisual.com\/fr\/#website\",\"url\":\"https:\/\/www.ergovisual.com\/fr\/\",\"name\":\"ErgoVisual\",\"description\":\"Control Room Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.ergovisual.com\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ergovisual.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ergovisual.com\/fr\/#organization\",\"name\":\"INTAM ERGOVISUAL SLU\",\"url\":\"https:\/\/www.ergovisual.com\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.ergovisual.com\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2022\/03\/logo-ergovisual.svg\",\"contentUrl\":\"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2022\/03\/logo-ergovisual.svg\",\"caption\":\"INTAM ERGOVISUAL SLU\"},\"image\":{\"@id\":\"https:\/\/www.ergovisual.com\/fr\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/ergovisual\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.ergovisual.com\/fr\/#\/schema\/person\/8671ae1b31596122e80c5645c58ce8e9\",\"name\":\"Albert San Jos\u00e9\",\"sameAs\":[\"http:\/\/www.ergovisual.com\"],\"url\":\"https:\/\/www.ergovisual.com\/fr\/author\/albert_ergovis\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HydroLogic Panel: Refroidissement Datacenter via le plancher sur\u00e9lev\u00e9 - ErgoVisual","description":"HydroLogic Panel, est une tuile situ\u00e9e sous le plancher sur\u00e9lev\u00e9 qui est en charge du refroidissement Datacenter avec une grande optimisation d'espace.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/","og_locale":"fr_FR","og_type":"article","og_title":"HydroLogic Panel: Refroidissement Datacenter via le plancher sur\u00e9lev\u00e9 - ErgoVisual","og_description":"HydroLogic Panel, est une tuile situ\u00e9e sous le plancher sur\u00e9lev\u00e9 qui est en charge du refroidissement Datacenter avec une grande optimisation d'espace.","og_url":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/","og_site_name":"ErgoVisual","article_published_time":"2021-03-04T09:04:58+00:00","article_modified_time":"2021-03-04T09:05:00+00:00","og_image":[{"width":2560,"height":1948,"url":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2020\/06\/high_v5.jpg","type":"image\/jpeg"}],"author":"Albert San Jos\u00e9","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Albert San Jos\u00e9","Dur\u00e9e de lecture estim\u00e9e":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#article","isPartOf":{"@id":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/"},"author":{"name":"Albert San Jos\u00e9","@id":"https:\/\/www.ergovisual.com\/fr\/#\/schema\/person\/8671ae1b31596122e80c5645c58ce8e9"},"headline":"HydroLogic Panel: Refroidissement Datacenter via le plancher sur\u00e9lev\u00e9","datePublished":"2021-03-04T09:04:58+00:00","dateModified":"2021-03-04T09:05:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/"},"wordCount":844,"publisher":{"@id":"https:\/\/www.ergovisual.com\/fr\/#organization"},"image":{"@id":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3-1024x683.png","keywords":["datacenter"],"articleSection":["Datacenter"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/","url":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/","name":"HydroLogic Panel: Refroidissement Datacenter via le plancher sur\u00e9lev\u00e9 - ErgoVisual","isPartOf":{"@id":"https:\/\/www.ergovisual.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#primaryimage"},"image":{"@id":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3-1024x683.png","datePublished":"2021-03-04T09:04:58+00:00","dateModified":"2021-03-04T09:05:00+00:00","description":"HydroLogic Panel, est une tuile situ\u00e9e sous le plancher sur\u00e9lev\u00e9 qui est en charge du refroidissement Datacenter avec une grande optimisation d'espace.","breadcrumb":{"@id":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#primaryimage","url":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3-1024x683.png","contentUrl":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2021\/01\/HYDROLOGIC-PANEL-3-1024x683.png"},{"@type":"BreadcrumbList","@id":"https:\/\/www.ergovisual.com\/fr\/refroidissement-datacenter\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.ergovisual.com\/fr\/service-de-salle-de-controle-360o\/"},{"@type":"ListItem","position":2,"name":"HydroLogic Panel: Refroidissement Datacenter via le plancher sur\u00e9lev\u00e9"}]},{"@type":"WebSite","@id":"https:\/\/www.ergovisual.com\/fr\/#website","url":"https:\/\/www.ergovisual.com\/fr\/","name":"ErgoVisual","description":"Control Room Solutions","publisher":{"@id":"https:\/\/www.ergovisual.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ergovisual.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.ergovisual.com\/fr\/#organization","name":"INTAM ERGOVISUAL SLU","url":"https:\/\/www.ergovisual.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.ergovisual.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2022\/03\/logo-ergovisual.svg","contentUrl":"https:\/\/www.ergovisual.com\/wp-content\/uploads\/2022\/03\/logo-ergovisual.svg","caption":"INTAM ERGOVISUAL SLU"},"image":{"@id":"https:\/\/www.ergovisual.com\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/ergovisual"]},{"@type":"Person","@id":"https:\/\/www.ergovisual.com\/fr\/#\/schema\/person\/8671ae1b31596122e80c5645c58ce8e9","name":"Albert San Jos\u00e9","sameAs":["http:\/\/www.ergovisual.com"],"url":"https:\/\/www.ergovisual.com\/fr\/author\/albert_ergovis\/"}]}},"_links":{"self":[{"href":"https:\/\/www.ergovisual.com\/fr\/wp-json\/wp\/v2\/posts\/4112","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ergovisual.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ergovisual.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ergovisual.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ergovisual.com\/fr\/wp-json\/wp\/v2\/comments?post=4112"}],"version-history":[{"count":0,"href":"https:\/\/www.ergovisual.com\/fr\/wp-json\/wp\/v2\/posts\/4112\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.ergovisual.com\/fr\/wp-json\/wp\/v2\/media?parent=4112"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ergovisual.com\/fr\/wp-json\/wp\/v2\/categories?post=4112"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ergovisual.com\/fr\/wp-json\/wp\/v2\/tags?post=4112"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}